24
Reg. 00
Reset Error & Manufacturer Identification
Byte 1 0
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Write RERR - - - Read Only
Read RERR 0 0 0 MID
RERR Reset Error (writing a 1 clears the error condition)
1
MID Manufacturer ID (always FC1
16
- C&H)
Notes:
1. This bit is set if a command error occurs. If an error exists, only reads or writes to this register are
allowed. The RERR bit must be cleared by writing a 1 to this bit before normal command operation
will resume. See 4.3.1 for further details.
Reg. 02
Device Identification
Byte 3 2
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Write - - - - Read Only
Read ETH 0 0 0 DID
ETH Ethernet Type (0 = wired, 1 = wireless (Wi-Fi))
DID Device ID (always FDB
16
- EM405D)
Reg. 04
Hardware Version
Byte 5 4
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Write Read Only Read Only
Read HW Major HW Minor
HW Major Major Version Level of EM405D Hardware
HW Minor Minor Version Level of EM405D Hardware
Reg. 06
Firmware Version
Byte 7 6
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Write Read Only Read Only
Read FW Major FW Minor
FW Major Major Version Level of EM405D Firmware
FW Minor Minor Version Level of EM405D Firmware
Figure 7. EM405D Registers