Manual Part No: 11028854
MODEL
EM405D
USER'S MANUAL
ETHERNET
M- MODULE
CARRIER
Vista de pagina 0
1 2 3 4 5 6 ... 47 48

Indice de contenidos

Pagina 1 - Manual Part No: 11028854

Manual Part No: 11028854 MODEL EM405D USER'S MANUAL ETHERNET M- MODULE CARRIER

Pagina 2

4 1.7 APPLICABLE DOCUMENTS ANSI/VITA 12-1996 American National Standard for The Mezzanine Concept M-Module Specification, Approved May 20

Pagina 3

5 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Verify that there has been no damage to the shipping container. If damage exists the

Pagina 4

6 There are two M-module mounting locations on the EM405D. Single-wide M-modules may be installed in either or both of the positions. A double-wide

Pagina 5

7 3.0 FUNCTIONAL DESCRIPTION 3.1 GENERAL The EM405D provides a mechanical and electrical interface between an Ethernet bus and up to two M-modules.

Pagina 6

8 3.1.3 M-module Interface The M-module interface provides the mechanism for the microcontroller to access the M-modules. It is implemented

Pagina 7

9 3.3 FRONT PANEL The front panel of the EM405D contains two openings for access to the M-modules’ front panel connections and three LED indicators

Pagina 9

11 4.0 OPERATING INSTRUCTIONS 4.1 GENERAL The EM405D is controlled through the Ethernet interface using the TCP/IP protocol to carry a simple comman

Pagina 10

12 RECOMMENDATION The EM405D is an embedded device without an input device or display that can be used to determine the current configurati

Pagina 11 - Carrier

13 of other tasks. In ad-hoc mode, wireless devices may communicate directly with each other and an access point is not needed. In this case, all de

Pagina 12 - MODULE B

ii COPYRIGHT C&H Technologies, Inc. (C&H) provides this manual "as is" without warranty of any kind, either express

Pagina 13 - POSITION B

14 4.2.6.1 Wed-based Configuration To use the wed-based interface to configure the wired EM405D, open a Java enabled web browser and e

Pagina 14

15 always starting with 00-20-4A identifying the manufacturer of the device. The last three parts of the number are unique to each unit. Exa

Pagina 15

16 4.2.7.1 Wed-based Configuration To use the wed-based interface to configure the wireless EM405D, open a web browser and enter the device’s IP add

Pagina 16

17 The defaults that are restored using the above procedure are those set by the manufacturer of the Ethernet device and not by C&H Technologies,

Pagina 17

18 Successful (0x00): The command completed successfully without error. Invalid Command (0x01): The first byte received was not a valid command-id

Pagina 18

19 4.3.2 Write Data command The Write Data command writes data to an EM405D control register or to a register residing on an M-module. The command

Pagina 19

20 Example (values shown hex): To read the Device Identification Register on the EM405D, send the following command: Command: cd md as ws a

Pagina 20

21 Example 4: Read 32 words starting at address 0x0 followed by 32 words starting at address 0x80 starting address = 0x0 block size = 32

Pagina 21

22 4.3.4.2 Block Read command The Block Read command reads a block of data from an M-module. Unlike the block write command, block read does

Pagina 22

23 4.3.5 EM405D Configuration/Status Registers The EM405D contains a set of registers that are used to identify the carrier, configure the carrier,

Pagina 23

iii DOCUMENT REVISION NOTICE C&H Technologies, Inc. makes every attempt to provide up-to-date manuals with the associated equipment. Occasion

Pagina 24

24 Reg. 00 Reset Error & Manufacturer Identification Byte 1 0 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write RERR - - - R

Pagina 25

25 Reg. 08 Reset & Trigger Control Byte 9 8 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write RSTB RSTA TLVL TIMP BTBD BTBM

Pagina 26

26 4.4 CONTROLLING THE TRIGGERS The carrier implements flexible trigger control capabilities providing the user with many options for using triggers

Pagina 27

27 The function of each M-module trigger line is fully dependent upon the M-module. Refer to the particular M-module’s documentation for further deta

Pagina 29

A-1 APPENDIX A - CONNECTORS Figure A-1. 9-Pin DSUB Connector PIN DESCRIPTION 1 +12V INPUT 2 +12V INPUT 3 +12V INPUT 4 TRIG

Pagina 31 - VARF 0 0 0 TEMP

B-1 APPENDIX B – WIRED ETHERNET DEFAULT SETTINGS The Ethernet interface device on the wired version of the EM405D contains many configurable setti

Pagina 32

B-2 Table B-1. Ethernet Interface Default Settings. (continued) Active Connection Active Connection None Telnet Mod N/A Terminal Type N/A Rem

Pagina 33 - °C = (TEMP – 281) / 4.6

B-3 Table B-1. Ethernet Interface Default Settings. (continued) Email Notification Domain Name blank Mail Server 0.0.0.0 Recipients (Collect

Pagina 34

iv INTRODUCTION This manual describes the operation and use of the C&H Model EM405D Ethernet M-Module Carrier (Part Number 11028850). T

Pagina 36

C-1 APPENDIX C – WIRELESS ETHERNET (Wi-Fi) DEFAULT SETTINGS The Ethernet interface device on the Wireless version of the EM405D contain

Pagina 37

C-2 Table C-1. Wireless Ethernet Configuration Default Settings. (continued) Enable Line Printer Daemon (LPD) True - Port 515 Enable RealPort

Pagina 38

C-3 Table C-1. Wireless Ethernet Configuration Default Settings. (continued) Advanced Serial Settings Enable Port Logging False Enable RTS Togg

Pagina 40

N O T E S:

Pagina 42

READER'S COMMENT FORM Your comments assist us in improving the usefulness of C&H's publications; they are an importan

Pagina 43

INSTRUCTIONS In its continuing effort to improve documentation, C&H Technologies, Inc. provides this form for use in submitting any comments

Pagina 44

v TABLE OF CONTENTS 1.0 GENERAL DESCRIPTION... 1 1.1 PURPO

Pagina 45

vi 4.3.5 EM405D Configuration/Status Registers ...23 4.4 CONTROLLING THE TRIGGERS..

Pagina 46

1 1.0 GENERAL DESCRIPTION The EM405D Ethernet M-Module carrier provides complete Ethernet connectivity to up to two industry standard single-wide or

Pagina 47

2 1.2.2 Specifications MAXIMUM RATINGS Parameter Condition Rating Units Operating Temperature 0 to +60 C Non-Operating Temperature -40 to

Pagina 48

3 1.3 Electrical The EM405D only requires a +12V DC power input. The +12V input is internally converted to the +3.3V power required by the carrier a