Specifications:
Implementation:
• All versions use either two (2), four (4) or eight (8)
ANSI/VITA Standard 16 Channel M-Modules
(MA203), each of which have the block diagram
shown above
• See the EM405D and EM405-8 on C&H web site for
further information on the instrument enclosure
mounting and dimensions.
Trigger/Sample Strobe Features:
• An external clock may be routed through one
mezzanine to a carrier trigger and back to the Event
Detector triggers to minimize skew between
channels
• One mezzanine’s clock may be used as a master in
a similar manner
External Trigger Inputs:
• 32 Channel Unit TTL
• 64 & 128 Channel Units TTL and LVDS
External Power (32 Channel Unit):
• AC Input 100 to 240VAC, 47 to 63Hz with furnished
adapter
• Alternatively DC powered by 12V, 1A
External Power (64 and 128 Channel Units):
• AC Input 85 to 265VAC, 47 to 63Hz
• Alternatively DC Powered by 36 to 75V
Software Driver:
• Windows DLL
• Soft Front Panel Executable
• Online Help
• LabWindows/CVI Function Panels
• ANSI-C Source Code
• LabView
Conformance:
• These modules will be CE compliant for Emissions,
Immunity and Safety
Ordering Information:
32 Channel Event Detector:
Model EM405D100 P/N 11030010-0001
64 Channel Event Detector:
Model EM405-8x106 P/N 11030010-0002
128 Channel Event Detector:
Model EM405-8x107 P/N 11030010-0003
Comentarios a estos manuales